Dwyer Series 3000 Photohelic

Dwyer Series 3000 Pressure Switch/Gage 3-in-One Indicating gage. Lo-Limit and Hi-Limit control

hotohelic® Switch/Gages function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic® design. The Photohelic® measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust setpoint indicators are controlled by knobs located on the gage face. Individual setpoint deadband is one pointer width - less than 1% of full scale. Setpoints can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).

PHOTOHELIC SENSING - HOW IT WORKS
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less - just enough to assure positive, chatter-free operation.

RELAY-TRANSFORMER FEATURES
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards (for the Series A3000 only).

APPLICATIONS - PHOTOHELIC SWITCH/GAGES
In both series of pressure switch/gages, you get the convenience of a visual indication plus high-low limit switching. For both OEM and in-plant applications, the Photohelic® switch/gage is used to control pressures in air conditioning systems, clean rooms, fluidic and pneumatic control systems, materials handling equipment, alarm or control fume exhaust systems, control pressure in air structures, and monitor respiratory and blood pressures.

STANDARD MODEL
Two phototransistor-actuated circuits and two DPDT relays permit both high and low alarms or limit controls. Relays are de-energized when gage pointer is to the left of respective set points; relays are energized as pointer passes to the right of set points. Loss of electrical power or loss of pressure provide "fail safe" protection.

Specifications:

GAGE SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult Factory.
Accuracy: ±2% of full scale at 70°F (21.1°C). ±3% on -0 and ±4% on -00 models.
Pressure Limits: -20" Hg. to 25 psig (-0.677 to 1.72 bar). MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar). 36003S – 36010S; 150 psig (10.34 bar). 36020S and higher; 1.2 x full scale pressure.
Temperature Limits: 20 to 120°F. (-6.67 to 48.9°C) Low temperature option available.
Process Connections: 1/8" female NPT.
Size: 4" (101.6 mm) dial face, 5" (127 mm) O.D. x 8-1/4" (209.55 mm).
Weight: 4 lb (1.81 kg).

SWITCH SPECIFICATIONS
Switch Type: Each setpoint has 2 Form C relays (DPDT).
Repeatability: ±1% of full scale.
Electrical Rating: 10A @ 28 VDC, 10A @ 120, 240 VAC;
Electrical Connections: Screw terminals.
Power Requirements: 120 VAC, 50/60 Hz (standard); 240 VAC & 24 VAC Power optional.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Set Point Adjustment: Adjustable knobs on face.
Agency Approvals: UL,CSA, CE.

Options:

HIGH AND LOW LATCHING CIRCUITS
Dwyer Photohelic switch/gages can be wired for high-latching, low-latching or combination high-low latching circuits. That is, the equipment will hold in these respective positions once activated and until manually reset. This can be particularly useful for alarm and signal applications where control is accomplished by another Photohelic® switch/gage or other means. Complete wiring and operational instructions are included. Where manual reset is required a dry circuit push button such as Dwyer Part A-601 should be used.

OPTIONS -- Consult Factory for Pricing
-SR Single contact, right set point, for actuation on increasing or decreasing pressure.
-OEM OEM Model, less relay and transformer components and housing but including infared diodes and phototransistor(s), light shutter and set pointer(s). For single or double contact.
-RMR Remote-Mounted Relay, relay pack may be mounted remotely from gage. Standard length is 5 ft. For other lengths, specify cable length required.
-TAMP Tamper-proof knobs, low temperature option, special scales, voltages and other features and modifications are available.
Special Housings available include Weatherproof (NEMA 4) and Explosion-proof (NEMA 7 & 9; NEC Cl I, Gr C&D; Cl II, Gr E, F&G; Cl III). Contact Gas Regulator Malaysia for detailed dimension drawings. 


Special Purpose Ranges
  Scale No. 3401 Square Root Specify Range
  Scale No. 3402 Blank Scale Specify Range

ACCESSORIES - Photohelic gauge
A-298 Flat Flush Mounting Bracket
A-601
Manual Reset Switch

Features:

Check These Features for Dependable Control

  1. Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® set point mechanism.Cover is clear polycarbonate plastic.
  2. Gage pointer and light shutter are mounted on helix and balancing counterweight. Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure
  3. Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement. It also gives interior a clean "finished" look.
  4. Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy.
  5. Semi-Flexible drive shaft connects to set point knobs.
  6. Zero adjustment screw connects to screw in cover to adjust zero pressure reading.
  7. Plastic enclosure protects electronic components and electrical connections.
  8. Polycarbonate connection or terminal board is self-extinguishing (A3000 only).
  9. Glass epoxy printed circuit boards for durability and permanence.
  10. Load relays are DPDT with latching feature for maximum application versatility.
  11. Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage. Special units for other voltages are available.
  12. Switch set pointers show switch settings at all times.
  13. Spring loaded friction clutch prevents operator damage of set point mechanism.

Series A3000 Photohelic® Pressure Switch/Gage Model Number Chart

Inches of w.c.

psi

Single Pressure - psi

Model Number

Range - Inches w.c.

 A3000-00

0-.25

 A3000-0

0-.50

 A3001

0-1.0

 A3002

0-2.0

 A3003

0-3.0

 A3004

0-4.0

 A3005

0-5.0

 A3006

0-6.0

 A3008

0-8.0

 A3010

0-10

 A3015

0-15

 A3020

0-20

 A3025

0-25

 A3030

0-30

 A3040

0-40

 A3050

0-50

 A3060

0-60

 A3080

0-80

 A3100

0-100

 A3150

0-150

Model Number

Range - psi

 A3201

0-1

 A3202

0-2

 A3203

0-3

 A3204

0-4

 A3205

0-5

 A3210¹

0-10

 A3215¹

0-15

 A3220¹

0-20

 A3230²

0-30

Model Number

Range - Inches w.c.

 A36003S

0-30

 A36006S

0-60

 A36010S

0-100

 A36020S

0-200

 A36030S

0-300

 A36060S

0-600

 A36100S

0-1000

 A36300S

0-3000

 A36600S

0-6000

 

 

Inches of w.c. - Zero Center

cm of w.c.

Model Number

Zero Center Range

 A3300-0

.25-0-.25

 A3301

.5-0-.5

 A3302

1-0-1

 A3304

2-0-2

 A3310

5-0-5

 A3320

10-0-10

 A3330

15-0-15

Model Number

Range - cm w.c.

 A3000-15CM

0-15

 A3000-20CM

0-20

 A3000-25CM

0-25

 A3000-50CM

0-50

 A3000-80CM

0-80

 A3000-100CM

0-100

 A3000-150CM

0-150

 A3000-200CM

0-200

 A3000-250CM

0-250

 A3000-300CM

0-300

 

 

 

Inches of w.c./Air Velocity, ft/min

mm of w.c.

kPa

Model Number

Range - Inches w.c.

 A3000-00AV³

0-.25

 A3000-0AV³

0-.50

 A3001AV³

0-1.0

 A3002AV³

0-2.0

 A3010AV³

0-10

Model Number

Range - mm w.c.

 A3000-6MM

0-6

 A3000-10MM

0-10

 A3000-25MM

0-25

 A3000-50MM

0-50

 A3000-80MM

0-80

 A3000-100MM

0-100

Model Number

Range - kPa

 A3000-1KPA

0-1

 A3000-1.5KPA

0-1.5

 A3000-2KPA

0-2

 A3000-3KPA

0-3

 A3000-4KPA

0-4

 A3000-5KPA

0-5

 A3000-8KPA

0-8

 A3000-10KPA

0-10

 A3000-15KPA

0-15

 A3000-20KPA

0-20

 A3000-25KPA

0-25

 A3000-30KPA

0-30

 

 

mm of w.c. - Zero Center

cm of w.c. - Zero Center

Model Number

Zero CenterRange

 A3300-20MM

10-0-10

 A3300-30MM

15-0-15

Model Number

Zero Center Range

 A3300-4CM

2-0-2

 A3300-10CM

5-0-5

 A3300-30CM

15-0-15

 

 

Pascals

kPa - Zero Center

Bi-Directional

Model Number

Range - Pascals

 A3000-60PA

0-60

 A3000-125PA

0-125

 A3000-250PA

0-250

 A3000-500PA

0-500

 A3000-750PA

0-750

Model Number

Zero Center Range

 A3300-1KPA

.5-0-.5

 A3300-3KPA

1.5-0-1.5

Model Number

Range - Inches w.c.

 A3000-00N

-.05 to +20 (For Room Pressure Monitoring)

Pascals - Zero Center

 

Model Number

Zero Center Range

 A3300-250PA

125-0-125

 A3300-500PA

250-0-250






 

 

 

 

1MP | 2HP option standard | 3Pitot tube required

Please contact Gas Regulator Malaysia for enquiries on this Photohelic Pressure switch / Gauge for your differential pressure switching needs. Series available A3000, 3000MR and 3000MRS.

 SeriesDescriptionProduct Page
Series DH3 Digihelic® Differential Pressure ControllerDigihelic® Controller in Photohelic® Gage, Square Root Output for FlowGo To Product Page
Series DHII Digihelic® Differential Pressure ControllerNEMA 4 (IP66) Housing with Large, Bright LCD, Square Root Output for FlowGo To Product Page
Series DH Digihelic® Differential Pressure Controller3 in 1 Instrument: Gage, Switch and Transmitter, Square Root Extractor for Air FlowGo To Product Page
Series ADPS Differential Pressure SwitchWith Dual Scale Field Adjustable Set Point KnobGo To Product Page
Series DCT1000 Dust Collector Timer ControllerModular Design, User Friendly, Up to 22 ChannelsGo To Product Page
Series MS Magnesense® Differential Pressure TransmitterMonitors Pressure & Air VelocityGo To Product Page

Contact us for Dywer Instruments products in Malaysia.