Series 605 Magnehelic® Differential Pressure Indicating Transmitter

Same Size as Standard Magnehelic® Differential Pressure Gage


The Series 605 Magnehelic® Indicating Transmitter 

provides for both visual monitoring and electronic control 

of very low differential pressure. The Series 605 is ideal for control applications in building 

HVAC systems where local indication is desired during routine maintenance checks or 

necessary when trouble shooting the system. The easily read dial gage is complimented 

by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer® Magnehelic®

 gage mechanical design and Series 600 transmitter technology. The two-wire design with 

terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 

10 to 35 VDC supply.

ModelDescription
605-0Differential pressure indicating transmitter, range 0-.50" w.c., max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
605-00NDifferential pressure indicating transmitter, range .05-0-0.2" w.c., max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy.
605-1Differential pressure indicating transmitter, range 0-1.0" w.c., max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±2% mechanical accuracy.
605-10Differential pressure indicating transmitter, range 0-10" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-11Differential pressure indicating transmitter, range .25-0-.25" w.c., max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
605-125PADifferential pressure indicating transmitter, range 0-125 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
605-2Differential pressure indicating transmitter, range 0-2.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-20Differential pressure indicating transmitter, range 0-20" w.c., max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-250PADifferential pressure indicating transmitter, range 0-250 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±2% mechanical accuracy.
605-3Differential pressure indicating transmitter, range 0-3.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-30Differential pressure indicating transmitter, range 0-30" w.c., max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-50Differential pressure indicating transmitter, range 0-50" w.c., max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-500PADifferential pressure indicating transmitter, range 0-500 Pa, max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-6Differential pressure indicating transmitter, range 0-6.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
605-60PADifferential pressure indicating transmitter, range 0-60 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy.



Product Applications

  • Monitor pressures in ducts, rooms, or total building pressures
  • Filter monitoring
  • Local indication of clean room pressures with process signal sent to control room